Puissance basse et moyenne tension

Transformateurs de puissance VPI/VPE

Puissance basse et moyenne tension

Transformateurs de puissance VPI/VPE

Localisateur d'agents

The VPI and VPE dry-type transformers from Rex Power Magnetics are built for reliability you can count on. In any commercial or industrial setting, your power network depends on every component working flawlessly 24/7—and your transformer should never be the weak link. With excellent insulation, thermal stability, and low-maintenance operation, our transformers deliver consistent performance indoors or out. Get specifications, consult our experts for a custom design, or request an estimate today.

 

Features & Benefits of VPI/VPE Power Transformers

Thanks to excellent engineering, our VPI and VPE transformers provide long-lasting performance. This is what distinguishes them:

Fully Resin-Impregnated Windings: Transformer lifespan is greatly increased by fully resin-impregnated windings, which offer an impenetrable barrier against dust and moisture. For VPI transformers, this is the industry standard.
Superior Thermal Stability: For steadfast dependability, our VPI/VPE technique guarantees great thermal stability by removing hot spots and reducing insulation breakdown.
UL-Listed and CSA-Certified: Every transformer satisfies strict industry safety standards and is UL-Listed and CSA-Certified, providing peace of mind.
Small, Quiet Design: Made to be small and silent, they enhance workspaces and are perfect for confined areas.
Enhanced Protection with VPE Process: To ensure maximum protection and a long transformer life in harsh environments, the VPE process applies a thick epoxy coating for unparalleled resistance to moisture and dirt.

What’s the difference between VPI and VPE?

Vacuum Pressure Impregnation (VPI) ensures that epoxy penetrates all voids within the windings, providing a high degree of thermal conductivity, and filling in tiny air voids reducing occurrence of partial discharges that can destroy insulation over time, particularly in medium voltage applications. VPI processing is standard for medium voltage (> 1.2kV class) transformers and reactors.
Vacuum Pressure Encapsulation (VPE) involves first completing the VPI process, and subsequently dipping the coils in epoxy which builds up additional external layers of protection, providing a superior degree of strength and resistance to moisture penetration above and beyond the VPI process.
Compared to liquid-filled transformers, dry-type VPI/VPE units are safer, eco-friendly, and require less maintenance, making them perfect for reliable power in industrial and commercial settings.

Rex Power Magnetics offers a wide range of VPI and VPE transformer models and configurations, ensuring a perfect fit for your specific needs:

Power Ratings: From 5 kVA to 15 MVA, with customizable solutions available.
Voltage Grades: Ranging from 600V to 44kV. Contact us for more information on medium voltage options.
Phase Configurations: Choose between single-phase or three-phase.
Enclosures: Various options to match your site’s requirements.
Bespoke Designs: Tailored solutions for unique project challenges.
Rex Power Magnetics offers a comprehensive range of related solutions, such as medium voltage and various dry-type versions, in addition to our VPI/VPE options.

transformer-k-rating

At Rex Power Magnetics, we know that off-the-shelf solutions don’t always cut it, especially when it comes to power. That’s why we excel at tailoring our to perfectly match your specific situation.

Our partners benefit greatly from our quick prototyping and attentive support staff. We ensure that your customized solution operates as intended by working closely together throughout the design and construction phases. Rex Power Magnetics is a reliable partner when it comes to power. Need a high-reliability power solution made just for you? Get in touch for engineering guidance and a fast track to optimized power performance.

Capacity  100 to 5,000 kVA Single Phase and 300 to 15,000 kVA Three Phase
Voltage Class  up to 46kV (250kV BIL)
Cooling  Air Cooled (ANN) [Optional Forced Air Cooled (AFN/AF)]
Frequency  60Hz [50/60Hz Optional]
Conductors  Copper (Cu) or Aluminum (Al) Windings
Insulation System  220°C (150°C Temperature Rise) [Optional 115°C & 80°C Rise Available]
Impregnation  Epoxy Vaccum Pressure Impregnated (VPI) and Baked [Optional VPE]
Efficiency  Meets North American Energy Efficiency Standards:

  • U.S. – (DOE 2016) DOE 10 CFR Part 431
  • Canada – (NRCan 2019) SOR/2018-201, Amd. 14 & ON Reg. 404/12
Primary Taps  Typically +/-2 x 2.5% taps
Sound Level  Meets IEEE C57.12.01
Configuration  Terminal Bus Stubs Suitable For Cables [Optional Unit-Substation or Padmount Configuration]
Enclosure Type  Type 1 Indoor [Type 2, 3R, 4, 4X & 12 Optional]
Enclosure Finish  ANSI 61 Grey Powder Coat
Testing  Std Production Tests (per IEEE C57.12.91)

  • Winding Resistance
  • Turns Ratio
  • Polarity and Phase Relation
  • No-Load Loss and Excitation Current
  • Load Loss & Impendance
  • Applied Potential
  • Induced Potential
 Optional Type Tests

  • Basic Insulation Level (BIL)
  • Temperature Rise (Heat Run)
  • Sound Level
  • Partial Discharge

Other Optional Tests

  • RIV
  • Power Factor
Warranty  18 Months (See Warranty and Limitations)
Quality System  ISO 9001:2015 Quality Management System
Certifications
  • CSA Certified
  • UL Listed
Reference Standards
  • CSA C22.2 No 47
  • CSA C9
  • IEEE C57.12.01
  • IEEE C57.12.91
Optional Features & Accessories
  • Provision for Future Fans or Fan Packages (AFN) completely installed with or without Control Power
  • Buss Co-ordination with primary and secondary switchgear (Unit-Substation configuration)
  • Dial (Analog) or Digital Thermometers to monitor winding temperatures
  • Neutral Ground Resistors (NGR) and Monitoring
  • Anti-Condensation Strip Heaters
  • Switching surge mitigating R.C. Snubbers (with or without ground current monitoring)
  • Ground Fault Protection Relays (GFR)
  • Anti-Vibration mounting to reduce transformer hum (sound level)
  • Provision for Seismic mounting or complete Seismic Snubbers and Restraints
  • Distribution, Intermediate or Station Class Surge Arrestors
  • Provision for Buss Duct Entry
  • Fully Insulated Buss
  • Mimic Buss
  • Kirk-Key Interlock
Photos
Videos

Shielded isolation transformers include a copper electrostatic shield between the primary and secondary windings, which helps reducing capacitive coupling between the windings, attenuating the transfer of high-frequency noise and transients from one system to the next. The primary advantages include superior noise suppression, improved protection against high-voltage spikes, and reduced risk of common-mode interference. The disadvantage is that shielded transformers can be more costly and larger in size compared to their non-shielded counterparts. In applications where high-frequency noise or voltage transients are a concern, the added investment in a shielded transformer is often justified.

Unless designed for special service conditions / environments, below are the standard service conditions for dry type distribution transformers:

  • Ambient Temperature: -40°C to + 30°C (max peak +40°C)
  • Relative Humidity: less than 70%
  • Altitude: up to 1000m (3300 ft.) above seal level

To ensure proper operation, avoid installing transformers in environments with excessive moisture, extreme temperatures, or direct sunlight. Maintain recommended clearances and keep all ventilation panels unobstructed.

Any transformer which is not installed and energized immediately should be stored in a dry, clean space having a uniform temperature to prevent condensation on the windings. Dry type transformers with resin dipped or epoxy vacuum impregnated coils can be stored at ambient temperatures as low as -50C. Transformers with encapsulated or epoxy cast coils should not be stored at ambient temperatures below -20C to prevent cracking of the epoxy. Preferably, transformers should be stored in a heated building having adequate air circulation and protected from cement, plaster, paint, dirt, and water or other gases, powders, and dust. The floor on which the transformer is being stored should be resistant to the upward migration of water vapor. Precautions should be taken to prevent storage in an area that water could be present, such as roof leaks, windows, etc. Condensation or absorption of moisture can be greatly reduced by keeping the transformer enclosure 5⁰C-10⁰C above ambient temperature. This can be easily achieved by the installation and energization of space heaters (optional). If the transformer is not furnished with internal space heaters, then external, portable heaters can be used. Note: Lamps or heaters should never come in direct contact with the transformer coil insulation.

It is not advisable to store a dry type transformer outdoors, but in the case that it is unavoidable, protective measures should be taken to prevent moisture and foreign debris from entering the transformer enclosure. The plastic wrapping supplied during shipment should be left in place, and a suitable drying agent such as silica gel packs should be used. The unit should also be checked periodically for indications of condensation on the windings, coil support blocks, core, core clamping system and bus/cables.

The minimum required clearances of a dry type transformer to walls, floors or other equipment must adhere to the local electrical code requirements.

In the absence of such requirements, Rex Power Magnetics recommends that dry type transformers be mounted so that there is an air space of no less than 150mm (6”) between the enclosures, and between the enclosure and any adjacent surface except floors. When the adjacent surface is a combustible material, the minimum permissible separation between the transformer enclosure and the adjacent surface should be 300mm (12”). Where the adjacent surface is the wall on which the transformer is mounted, the minimum permissible separation between the enclosure and the mounting wall should be 6mm (0.25”) so long as the surface is of a non-combustible material.

In dry-type transformers, the surrounding air plays a critical role in their operation. Generally, low ambient temperatures do not negatively impact an energized transformer, as the no-load losses typically generate enough heat to maintain proper conditions, even in environments as cold as -40°C. However, transformers stored at low temperatures present two primary concerns:

  • Insulation Brittleness: At low temperatures, the insulation in the coils may become brittle. Expanding conductors when a cold transformer is loaded, or contracting conductors during cold storage, may cause cracks in the insulation, leading to internal faults.
  • Condensation Risk: Low temperatures can cause condensation inside the transformer enclosure, as well as on the transformer coils. Energizing a transformer with condensation present on the coils can lead to internal faults and insulation damage.

Rex Power Magnetics recommends testing transformers (megger testing), warming them to above 0°C, or following a drying-out procedure if moisture is suspected. Refer to Rex Power Magnetics’ cold start procedures to ensure safe energization in cold conditions. Energizing a transformer with compromised insulation due to moisture can cause damage and potential safety hazards.

Cold Start Procedure

The life expectancy of a dry-type transformer is primarily determined by the insulation system and the operating temperature. According to IEEE Std. C57.96, the deterioration of insulation is directly related to the time and temperature the transformer experiences during operation. Insulation materials degrade faster at higher temperatures, so the transformer’s life expectancy is closely tied to how well it is kept within its design temperature limits.

In most transformers, the highest temperature occurs at a specific point in the windings, known as the hot spot. This area undergoes the most significant wear over time, making it the primary factor in determining the transformer’s ageing process.

All of Rex Power Magnetics’ dry-type transformers are designed using UL-listed insulation systems with a maximum hot spot temperature that ensures a design life of at least 30 years under standard operating conditions (continuous rated load, typical ambient temperatures, and no sustained overloads). Transformers designed with reduced temperature rise can extend this design life expectancy to over 50 years, as operating at lower temperatures slows the insulation’s ageing process.

Factors That Affect Life Expectancy:

  • Temperature: As discussed, the most significant factor is the operating temperature of the transformer. Operating continuously at higher temperatures reduces the expected lifespan.
  • Humidity and Condensation: Humid environments or condensation can affect the insulation material and lead to premature failure. Proper storage and maintenance help mitigate this risk.
  • Short Circuit Events: Sudden surges or short circuits can damage internal components and shorten the transformer’s life.
  • Overloading: Continuous overloading beyond the transformer’s rated capacity generates excess heat, which accelerates insulation degradation.
  • Environmental Conditions: Extreme environments, such as exposure to dust, moisture, or chemicals, can also lead to earlier-than-expected failure.

By following proper installation and maintenance practices, such as avoiding overloading and ensuring the transformer operates within its designed ambient temperature, you can significantly extend its lifespan. Rex Power Magnetics’ high-quality transformers are built for durability, ensuring reliable performance for decades under standard conditions.

It`s normal for new transformers to release some harmless odors from the varnish impregnation used in the coils for a week or two after energization. Older Transformers can also release some odor if loaded to a higher level than they have experienced previously in their history.

Rex Power Magnetics’ ventilated distribution transformer terminals are rated 90°C. Conductors with at least a 90°C insulation rating at or below their 90°C ampacity rating should be utilized.

Voltage regulation refers to the voltage drop on the secondary side of the transformer from no load to full load. The voltage drop is a function of the percentage loading and the power factor of the load. Low voltage distribution isolation transformers generally have a voltage regulation which will range between 1-3% at full load for load with a power factor of 1, and 2-5% at full load for load with a power factor of 0.8.

Entreprise canadienne de conception et de fabrication de transformateurs à sec