Reactors & Filters

AC Line/Load Reactors

Reactors & Filters

AC Line/Load Reactors

Agent Locator

Rex Power Magnetics AC Line and Load Reactors are designed to improve power quality, protect equipment, and extend the life of electrical systems. Installed on the line or load side of variable frequency drives (VFDs), motor controllers, and other sensitive equipment, these reactors limit harmonic distortion, reduce voltage spikes, and mitigate current surges.

Each reactor is engineered for precise inductance, low losses, and superior thermal performance. Constructed using high-grade core steel, copper or aluminum windings, and robust insulation systems, Rex reactors provide reliable operation under continuous and transient conditions. Their dry-type construction and durable enclosures make them suitable for harsh industrial environments.

Available in a wide range of current ratings and voltage classes, Rex AC Line and Load Reactors can be tailored to specific system requirements. All units are designed and tested to meet applicable CSA and UL standards, ensuring safe, efficient, and long-lasting performance in demanding applications.

Capacity  2A to 1,250 A Three Phase
Voltage Class  600V Max
Cooling  Air Cooled (ANN / AN)
Frequency  60Hz (50/60Hz Optional)
Conductors  Copper (Cu) Windings
Insulation System  220°C Insulation System (150 °C Temp Rise Max)
Sound Level  Below 40dBA
Overload Capability  150% of rated current for 1 min.
Saturation Level  Not less than 250% of rated current (min 50% of rated inductance at 350% rated current)
Enclosure Type   Type 1 Indoor
Warranty  12 Months (See Warranty and Limitations)
Quality System  ISO 9001:2015 Quality Management System
Certifications
  • CSA Certified
  • UL Listed
Reference Standards
  • IEEE C57.110
  • NEMA ST-20
Rating
HP
Voltage= 208 Volts Voltage= 240 Volt
Maximum
Current
(Amps)
Impedance Maximum
Current
(Amps)
Impedance
3% 5% 3% 5%
1
1.5
2
4
8
8
3PR-0004C3L
3PR-0008C3L
3PR-0008C3L
3PR-0004C5L
3PR-0008C5L
3PR-0008C5L
4
8
8
3PR-0004C3L
3PR-0008C3L
3PR-0008C3L
3PR-0004C5L
3PR-0008C5L
3PR-0008C5L
3
5
7.5
11
17
27
3PR-0011C3L
3PR-0017C3L
3PR-0027C3L
3PR-0011C5L
3PR-0017C5L
3PR-0027C5L
11
17
27
3PR-0011C3L
3PR-0017C3L
3PR-0027C3L
3PR-0011C5L
3PR-0017C5L
3PR-0027C5L
10
15
20
34
45
60
3PR-0034C3L
3PR-0045C3L
3PR-0060C3L
3PR-0034C5L
3PR-0045C5L
3PR-0060C5L
27
45
60
3PR-0027C3L
3PR-0045C3L
3PR-0060C3L
3PR-0027C5L
3PR-0045C5L
3PR-0060C5L
25
30
40
80
100
130
3PR-0080C3L
3PR-0100C3L
3PR-0130C3L
3PR-0080C5L
3PR-0100C5L
3PR-0130C5L
80
80
100
3PR-0080C3L
3PR-0080C3L
3PR-0100C3L
3PR-0080C5L
3PR-0080C5L
3PR-0100C5L
50
60
75
160
160
200
3PR-0160C3L
3PR-0160C3L
3PR-0200C3L
3PR-0160C5L
3PR-0160C5L
3PR-0200C5L
130
160
200
3PR-0130C3L
3PR-0160C3L
3PR-0200C3L
3PR-0130C5L
3PR-0160C5L
3PR-0200C5L
100
125
150
255
320
410
3PR-0255C3L
3PR-0320C3L
3PR-0410C3L
3PR-0255C5L
3PR-0320C5L
3PR-0410C5L
255
320
410
3PR-0255C3L
3PR-0320C3L
3PR-0410C3L
3PR-0255C5L
3PR-0320C5L
3PR-0410C5L
200
250
300
500
600
750
3PR-0500C3L
3PR-0600C3L
3PR-0750C3
3PR-0500C5L
3PR-0600C5L
3PR-0750C5
500
600
750
3PR-0500C3L
3PR-0600C3L
3PR-0750C3
3PR-0500C5L
3PR-0600C5L
3PR-0750C5
350
400
500
1000
1000
1250
3PR-1000C3
3PR-1000C3
3PR-1250C3
3PR-1000C5
3PR-1000C5
3PR-1250C5
1000
1000
1250
3PR-1000C3
3PR-1000C3
3PR-1250C3
3PR-1000C5
3PR-1000C5
3PR-1250C5

An AC line/load reactor is an inductive device installed in series with either the input (line side) or output (load side) of variable frequency drives (VFDs) or other power electronic equipment. It limits current surges, reduces harmonic distortion, and protects sensitive components from transients. Rex Power Magnetics AC reactors improve power quality and extend equipment life by mitigating voltage spikes, reducing current distortion, and filtering unwanted noise from the electrical system.

Reactors limit harmonic distortion, reduce motor noise, and improve current waveform quality. They also help achieve compliance with IEEE 519 harmonic distortion limits. Line reactors reduce the risk of nuisance drive tripping due to voltage spikes or sags, while load reactors protect motor insulation from reflected wave voltages. The result is smoother operation, lower maintenance, and extended equipment life for both VFDs and motors.

Yes. Rex Power Magnetics specializes in custom line and load reactors tailored to specific drive, voltage, or harmonic requirements. Options include custom inductance values, current ratings, terminal configurations, and enclosure types. Engineering teams perform system-level analysis to optimize performance for harmonic mitigation, voltage waveform improvement, and equipment protection. Each custom reactor is fully tested and certified to ensure compliance and long-term operational reliability.

Each reactor uses high-grade electrical steel laminations and precision-wound copper or aluminum conductors. The core and coils are dipped in polyester resin to improve mechanical rigidity, insulation integrity, and moisture resistance. This coating reduces vibration and noise while protecting against environmental contaminants. Reactors are air-cooled and designed for continuous-duty service, with thermal and mechanical bracing that ensures stability under short-circuit and harmonic loading conditions.

AC reactors are rated by their inductance (in millihenries) or percentage impedance (%Z) at a given current. Common ratings are 3% or 5% impedance, which determine the degree of harmonic reduction and transient suppression. Rex Power Magnetics engineers select core materials and conductor sizes to maintain linear performance under full-load current without core saturation. Custom ratings and tolerances can be provided for unique system conditions or harmonic profiles.

AC reactors are used in drive systems, harmonic filters, renewable energy installations, and industrial power distribution networks. Common applications include pumps, conveyors, HVAC systems, compressors, and automated manufacturing lines. They are also used in systems with frequent switching or long motor lead lengths where voltage reflections or high dV/dt may occur. Rex Power Magnetics reactors are suitable for industrial, commercial, and OEM applications requiring enhanced electrical protection and power quality.

Reactors protect both the drive and the motor from electrical stress. They dampen voltage transients, filter switching harmonics, and reduce the effect of power line disturbances on drive operation. When installed on the line side, they prevent nuisance tripping and extend VFD lifespan. On the load side, they reduce cable stress, protect motor insulation, and minimize electromagnetic interference. Rex Power Magnetics reactors help ensure stable and reliable operation in harmonic-rich environments.

Custom solutions for the systems that keep your industry running

Get Quote